If you happen to purchase a modem from a friend, online, or received a modem for another ISP, don't worry there's still hope! WARNING!! This should be for advanced users only. This may cause serious problems to your dsl modem if the necessary precautions are not taken. Again, only do this if you find out your modem is unable to sync on your line. For the SpeedStream 4060/3060: At this time, there is no defined software to change this. For the Westell Wirespeed: At the main screen of the program, hit ctrl+alt+f7. Proceed to the PVC tab. The following items are found: VPI and VCI Table. If you do not know your VPI/VCI contact your local telco. They will tell you; but don't disclose what ISP you use. Otherwise, try these common settings from across the globe:
(List Credit to »steve-parker.org) So if you're in the US, try using either 0/35 or 8/35. One of those settings will allow your modem to sync on the line. Scroll down on the VPI or VCI. Go to the VCI or VPI table and select the correct number. Click EDIT VCI or EDIT VPI and click "enable" and then OK. Click apply again. Close and reboot modem. ActionTec Hybrid: At the main screen of the program, hit ctrl+p Go to the configurations tab configure settings there. they are similar to the one above. Broadxent Blaster: Set your device to IP: 192.168.1.2 Subnet: 255.255.255.0 Restart In your web browser put 192.168.1.1 username: USER PASSWORD: 8012U configure through the web interface. If configured properly, the modem should sync. Feedback received on this FAQ entry: